Power supply :DC24V Built-in /O points :16 I/O,DI 6*DC24V,DIO 4*DC24V,DO 6*Relay,relay output Communication ports :Micro USB2.0, 2 RS485, Connectable expansion modules :No Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 4K steps; User data memory--M area 1KB,V area 4KB;…
Power supply :DC24V Built-in /O points :16 I/O,DI 6*DC24V,DIO 4*DC24V,DO 6*DC24V transistor output, Communication ports :Micro USB2.0, 2 RS485, Connectable expansion modules :No Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 4K steps; User data memory--M area 1KB,V…
Power supply :DC24V Built-in /O points :18 I/O, DI 8*DC24V,DO 8*DC24V,transistor output,1 AI,1 AO Communication ports :Micro USB2.0, 2 RS485, Connectable expansion modules :No Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 4K steps; User data memory--M area 1KB,V…
Power supply :DC24V Built-in /O points :22 I/O, DI 8*DC24V,DIO 6*DC24V,DO 8*DC24V,transistor output Communication ports :Micro USB2.0, 2 RS485, Connectable expansion modules :No Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 4K steps; User data memory--M area 1KB,V area…
Power supply :DC24V Built-in /O points :50 I/O, DI 22*DC24V,DO 8*DC24V+12*Relay,6*AI,2*AO Communication ports :Micro USB2.0, 2 RS485,1 RS232 Connectable expansion modules :No Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 4K steps; User data memory--M area 1KB,V area 4KB;…
Power supply :DC24V Built-in /O points :56 I/O, DI 32*DC24V,DO 24*DC24V,transistor output, Communication ports :Micro USB2.0, 2*RS485, 1*CAN,1*expansion port ( also be CAN interface at the same time, support CAN free communication). Connectable expansion modules :Yes, Support KS series expansion modules Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 8K steps; …
Power supply: DC20.4-28.8V power supply Built-in I/O points: 30 I/O, DI 14*DC24V, DO 10*DC24V, DO is transistor output, AI 4*IV, AO 2*IV, AI/AO support…
Input points: 8, divided into 2 groups, each group with 4 channels Input type: Source (common-cathode)/sink (common-anode) Input voltage: Rated DC24V, voltage range of logic "1" is DC11~30V Isolation mode: Opto-coupler isolation between input signal and internal circuit, isolation voltage 500VAC/1 min Signal indication: Separated…
Input points: 16, divided into 2 groups, each group with 8 channels Input type: Source (common-cathode)/sink (common-anode) Input voltage: Rated DC24V, voltage range of logic "1" is DC11~30V Isolation mode: Opto-coupler isolation between input signal and internal circuit, isolation voltage 500VAC/1 min Signal indication: Separated LED…
Output points: 8, divided into 2 groups, each group with 4 channels Output type: source (common-cathode) Output voltage: Rated DC24V, max. output current of each channel is 500mA Circuit protection: Power supply access polarity protection, output short-circuit protection, inductive load protection Isolation mode:…
Output points: 8, divided into 2 groups, each group with 4 channels. Output type: source (common-cathode). Load voltage: Max. DC30V/AC250V, max. load current of each channel is 2A. Isolation mode: Opto-coupler isolation between coil and contact, isolation voltage 2000Vrms. Signal indication: LED indicates for each…
Output points: 16, divided into 4 groups, each group with 4 channels Output type: source (common-cathode) Output voltage: Rated DC24V, max. output current of each channel is 500mA Circuit protection: Power supply access polarity protection, output short-circuit protection, inductive load protection Isolation mode:…
Output points: 16, divided into 4 groups, each group with 4 channels. Output type: source (common-cathode). Load voltage: Max. DC30V/AC250V, max. load current of each channel is 2A. Isolation mode: Opto-coupler isolation between coil and contact, isolation voltage 2000Vrms. Signal indication: Separated LED indicates for…
Input point: 4, totally classified into 1 group Input type: Source (common-cathode)/sink (common-anode) Input voltage: Rated DC24V, voltage range of logic "1" is DC11~30V Output point: 4, totally classified into 1 group Output type: Relay Load voltage: Max. DC30V/AC250V, max. load current of each channel is 2A Isolation mode: DI channels adopt opto-coupler isolation, …
I/O point: 8, DI 4*DC24V, DO 4*DC24V Input type: Source (common-cathode)/sink (common-anode) Input voltage: Rated DC24V, voltage range of logic "1" is DC11~30V Output type: Transistor Output voltage: Rated DC24V, max. output current of each channel is 0.5A Isolation mode: Opto-coupler isolation Signal indication: Separated LED indicates for each channel Module width: 50mm.
Input point: 8, totally classified into 1 group Input type: Source (common-cathode)/sink (common-anode) Input voltage: Rated DC24V, voltage range of logic "1" is DC11~30V Output point: 8, divided into 2 groups, each group with 4 channels Output type: Relay Load voltage: Max. DC30V/AC250V, max. load current of each channel is 2A Isolation mode: DI channels adopt opto-coupler isolation, …
I/O point: 16, DI 8*DC24V, DO 8*DC24V Input type: Source (common-cathode)/sink (common-anode) Input voltage: Rated DC24V, voltage range of logic "1" is DC11~30V Output type: Transistor Output voltage: Rated DC24V, max. output current of each channel is 0.5A Isolation mode: Opto-coupler isolation Signal indication: Separated LED indicates for each channel Module width: 75mm
Input channel: 4 Input signal: 4-20mA, 1-5V, 0-20mA, 0-10V signals are optional Measurement accuracy: 0.3% F.S Parameter configuration: Parameters of each channel can be configured by Kincobuilder software separately Signal limitation: Input current of each channel shall not exceed 24mA, input voltage shall not exceed 12V Error indication: Red LED of each channel indicates input signal exceeds measurement range Module…
Input channel: 4 Input signal: J type, K type, E type, S type, internal/external compensation selectable Measurement range: J type -210~1200℃, K type -270~1300℃, E type -120~1000℃, S type -50~1600℃ Measurement accuracy: 0.1%F.S. Parameter configuration: Independent parameter configuration can be made for each channel …
Output channel: 2 Signal type: 4-20mA, 1-5V, 0-20mA, 0-10V signals are optional Output accuracy: 0.3%F.S. Parameter configuration: Parameters of each channel can be configured by Kincobuilder software separately Signal limitation: The value of output channel is not allowed to exceed chosen range Module width: 50mm
Input channel: 2. 4-20mA, 1-5V, 0-20mA, 0-10V signals are optional Measurement accuracy: 0.3% F.S Output channel: 2. 4-20Ma, 1-5V, 0-20mA, 0-10V signals are optional Output accuracy: 0.3%F.S. Parameter configuration: Parameters of each channel can be configured by Kincobuilder software separately Signal limitation: Input current of each channel shall not exceed 24mA, input voltage shall not exceed 12V …
Function: CANopen master station and CAN free protocol communication Communication baudrate: Support 10K~1Mbps Electrical isolation: Power supply, communication circuit are separated from external, Isolation voltage is max. 2500VAC/1 min. Signal indication:Separated LED indicates power, working status, communication status. Module width: 50mm Specification of CANopen master station - Adopt CAN2.0 standard. Comply with standard CANopen protocol DS301 V4.2.0; - Support…
Voltage: AC85-265V Output rated current: 5V 1A/24V 250mA Signal display: PW light will be on when the power supplier is correct. Module width: 75mm Main Features: - PS580 doesn't need to configure in software. - PS580 doesn't use the address of I/O image area. - PS580 won't be counted as CPU expansion module. - If the expansion modules is…
AC100-240V,DI 14*DC24V,DO 10*DC24V,AI 4*IV,AO 2*IV Communication port:2*RS485,1*Ethernet 2 expansion BD board can be connected 14 expansion modules can be connected
DC24V,DI 14*DC24V,DO 10*DC24V,AI 4*IV,AO 2*IV Communication port:2*RS485,1*Ethernet 2 expansion BD board can be connected 14 expansion modules can be connected
Power supply :DC24V Built-in /O points :4*DI Communication ports :Micro USB2.0, 1 Ethernet, 1*RS232, 1*RS485, 1*CAN,1*expansion port( also be CAN interface at the same time, support CAN free communication). Connectable expansion modules :Yes.At most 14 expansion modules Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 8K steps; …
Power supply :DC24V Built-in /O points :16 I/O,DI 8*DC24V,DO 8*DC24V, transistor output Communication ports :1*RS232 , 1*RS485 Connectable expansion modules :Yes.At most 14 expansion modules Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 4K steps; User data memory--M area…
Power supply :DC24V Built-in /O points :16 I/O,DI 8*DC24V,DO 8*DC24V, transistor output Communication ports :1 CAN , 1 RS232 , 1 RS485 Connectable expansion modules :No Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 4K steps; User data memory--M…
Power supply :DC24V Built-in /O points :16 I/O, DI 8*DC24V,DO 8*DC24V, transistor output Communication ports :1 RS232 ,1 RS485, 1*CAN,1*expansion port ( also be CAN interface at the same time, support CAN free communication). Connectable expansion modules :Yes.At most 14 expansion modules Real-time clock :Yes, deviation less than 5 min/month at 25℃ Memory area :User program memory--Max 4K steps; …
Power supply :DC24V Input point :16,divided into 2 groups,each group with 8 channels Input type :Source / Sink Input voltage :Rated DC24V, voltage range of logic "1" is DC11-30V Isolation method :Photoelectric isolation between the signal and internal circuit. Isolation voltage 500VAC…
Power supply :DC24V Output points :12,divided into 3groups,each group with 4 channels Output type :Relay Load voltage :Max. DC30V/AC250V,max.load current of each channel is 2A Isolation method :Relay,Isolation voltage of coil and contacts 1500VAC / 1 min Installation size :100*84.5*25.4mm(mm)(L×W×H)
Power supply :DC24V Output point :14,divided into 2 groups Output type :Source Output voltage :Rated DC24V, max. output current of each channel is 500mA Circuit protection :Power supply access polarity protection、Output short circuit protection、Inductive load output protection Isolation method :Photoelectric isolation…
Power supply :DC24V Input point :8,totally classified into 1 group Input type :Source / Sink Input voltage :Rated DC24V, voltage range of logic "1" is DC11-30V Output point :6,divided into 2 groups Output type :Relay Load voltage :Max. DC30V/AC250V,max.load current of each channel is 2A Isolation method :DI channel adopts opto-coupler isolation …
Power supply :DC24V Input channel :4 Input signal :Pt100、Pt1000、Cu50、Resistor are selectable,2 wire or 3wire Measurement range :Pt100 -200~850℃、Cu50 -50~150℃、Pt1000 -50~300℃、 Resistorce 0~2000Ω Measurement accuracy :Temperature±0.5℃;Resistance±1Ω Parameter configuration :Each channel is individually parameterized through …
Power supply :DC24V(DC20.4V-DC28.8V) Built-in /O points :12 I/O, 8*DI,4*DIO Expansion module :Up to 14 KS series expansion modules High-speed input :4, support single phase and AB phase, Max. : 200KHz High-speed output :2, support pulse + direction, Max. : 200KHz. (The resistor of load must be less than 1.5KΩ) Wired communication port :1*MicroUSB(Programming port), 1*RS232, 1*RS485, …
Power supply :DC24V(DC20.4V-DC28.8V) Built-in /O points :12 I/O, 8*DI,4*DIO Expansion module :Up to 14 KS series expansion modules High-speed input :4, support single phase and AB phase, Max. : 200KHz High-speed output :2, support pulse + direction, Max. : 200KHz. (The resistor of load must be less than 1.5KΩ) Wired communication port :1*MicroUSB(Programming port), 1*RS232, 1*RS485, …
DC24V,4.3 TFT display, DI 9*DC24V,DO 9*DC24V,2*AI (only support voltage type), USB2.0 Programming port (PLC&HMI sharing same programming port) PLC part 2*RS485 COM port, Supports up to 8 Kinco KS series expansion modules. HMI part provides Ethernet interface, supports access to external network or other Ethernet devices.
DC24V,7 TFT display, DI 16*DC24V,DO 4*DC24V and 12*Relay USB2.0 Programming port (PLC&HMI sharing same programming port) PLC part 2*RS485 COM port, Supports up to 8 Kinco KS series expansion modules. HMI part provides Ethernet interface, supports access to external
DC24V,7 TFT display, DI 16*DC24V,DO 14*DC24V,2*AI,1*AO, USB2.0 Programming port (PLC&HMI sharing same programming port) PLC part 2*RS485 COM port, Supports up to 8 Kinco KS series expansion modules. HMI part provides Ethernet interface, supports access to external network or other Ethernet devices.