KC100 Series Inverter

KC100 High-performance Variable Frequency Drive

  • Only 65mm wide, easy of installation;
  • European crimping terminal, IO terminals without tightening screws, can improve install efficiency by 30%;
  • Support network port connected to external keyboard and use standard MODBUS communication protocol and scheme;
  • Various frequency given channel selections such as panel, analog, communication, pulse, PID, multi-speed, etc.
  • Built-in AVR, over-modulation, instantaneous non-stop and other functional

Product Information

Voltage: Single-phase 220V/0.4-2.2kW and Three-phase 380V/0.75-5.5kW

Communication: Modbus RS485


PDF Download

Product Catalogue :- Kinco catalog – KC100

User MAnual :- Kinco KC100 Series User Manual V1.3

SKU: KC100 Series Inverter Categories: , , Tags: ,
Available on Request - Enquire Now

Description

■ Major Features:

• Overcurrent suppression protection: real-time current monitoring, automatically limit the current to no more than the overcurrent suppression point;

• Overvoltage suppression protection: When no brake resistor is connected, the operating frequency is automatically adjusted or the bus voltage rise is suppressed by flux braking.

• Undervoltage suppression protection (instantaneous non-stop): It can realize the function of instantaneous power loss without stopping;

• Wave-by-wave current limiting: When the sudden load or abnormal conditions such as momentary spikes in the current occurs, it will trigger the wave-by-wave current limit protection, which can limit the rise of the current to a certain extent, so that the current does not exceed the protection value of the inverter, and avoid reporting overcurrent fault and shutdown;

• Heat dissipation treatment: Independent air duct design, close to the IGBT power device efficient cooling, while the software built-in automatic reduction of carrier frequency according to temperature rise;

• Overvoltage, overcurrent fault protection;

• Input phase loss: Detect input phase loss based on bus voltage fluctuations. When phase loss occurs, a certain load is required to detect it;;

• Output phase loss: Output phase loss fault can be quickly detected before and during operation;

• Phase to phase short circuit and short circuit to ground fault: quickly detected within 20ms before operation;

• Inverter module overtemperature, parameter self-learning failure, current detection failure, SVC stall failure, etc.

 

■ Industry applications

• HVAC, sewage treatment, manufacturing production lines, fan ventilation systems, logistics and transportation, air conditioner cooling systems, woodworking machinery, and various automated production equipment and other industries.

■ Specifications of KC100 Series Inverter

 

Inverter model Power supply capacitykVA input currentA output currentA Adaptive motorkW
single-phase 200-240V 50Hz/60Hz
KC100-2S-0R40G 1.0 5.3 2.5 0.4
KC100-2S-0R75G 1.5 8.2 4.0 0.75
KC100-2S-01R5G 3.0 14.0 7.5 1.5
KC100-2S-02R2G 4.0 23.0 10.0 2.2
three-phase 380-480V 50Hz/60Hz
KC100-4T-0R75G 1.5 3.4 2.3 0.75
KC100-4T-01R5G 3.0 5.0 3.7 1.5
KC100-4T-02R2G 4.0 5.8 5.5 2.2
KC100-4T-03R7G 5.9 10.5 8.8 3.7
KC100-4T-05R5G 8.5 14.5 13.0 5.5

For more information, please download and consult the selection manual.