B2341 Codesys PLC Modbus TCP Programable Controller

The B2341 programming environment is Codesys, a programmable controller that
follows the IEC61131-3 international standard, and supports five programming
languages: ladder diagram (LD), instruction list (IL), structured text (ST), function
block diagram (CFC), and sequential function diagram (SFC).

The maximum number of expansion modules is 4, the user program storage supports 1 Mbytes,
the power-down protection zone is 4 Kbytes, and Modbus TCP client and server are supported.

It has rich instructions, reliable functions, good adaptability, compact structure, easy
to expand, cost-effective, strong versatility, programming, monitoring, debugging, and
on-site operation are very convenient, and the Ethernet interface on the CPU supports
Modbus TCP client function, and supports access to the data of the third-party
Modbus TCP server.

Supports Modbus TCP server function and supports third-party Modbus TCP clients to access data.

Supported I/O expansion modules include:
A. Digital input module
B. Digital output module
C. Analog input module
D. Analog output module
E. Special function module


PDF Download : B2341 Manul

SKU: B-Series Categories: , Tag:
Available on Request - Enquire Now

Description

Product Details

Technical Parameters

General Parameters

System Power Supply: 19.2-28.8VDC (nominal: 24VDC) Protection: power supply anti-reverse polarity protection
Power Consumption 100mA@24VDC
Internal BUS Supply Current Max.2.5A@5.0VDC
Isolation The system power to field power: isolation
IO Modules Supported B32:2 B64:4
Wiring Max.1.5mm² (AWG 17)

Environment Specification

Operating Temperature of Vertical Installation -20℃~60℃
Operating Temperature of Horizontal Installation -20℃~50℃
Relative Humidity 5%~95%RH, no condensation
Storage Temperature -40℃~85℃
Storage Humidity 5%~95%RH, no condensation
Ingress Protection Rating IP20
EMC specifications Comply with IEC61131-2, IEC61000-4

Programming Specifications

Programming Software Codesys V3.5.19.70
Programming Language IEC61131-3(LD, IL, ST, CFC, SFC)
Maximum Task Status 5
Program Memory 1M Bytes
Data Storage 1M Bytes
Power-down Protection Area 3K Bytes
Maximum Expansion Module Input 1K Bytes
Maximum Expansion Module Output 1K Bytes
Maximum Number of Tasks 5
Bitwise Operations Cycle 0.21us
Word Operation Cycle 0.21us
Double Word Operation Cycle 0.64us
Minimum Program Run Cycle 1ms
RTC Not supported

Communication Parameters

Communication Interface 2*RJ45
Network Port Parameters 10/100Mbpa self-adaptive, full-duplex
Modbus TCP Client Supports up to 5 Modbus TCP server connections
Modbus TCP Server Supports up to 5 Modbus TCP client connections