MG-CANEX Protocol Converter CANopen to Modbus TCP protocol converter MG-CANEX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending. As a…
♦ Supports protocol conversion between Modbus and PROFIBUS ♦ Supports RS485, RS422 and Rs232 ♦ Supports Modbus master and slave, and supports RTU or ASCII ♦ Supports working environment of -40~85°C ♦ PROFIBUS-DP: Max. Input 244 bytes, Max. Output 244 bytes ♦ DPM01:1-way Modbus to PROFIBUS slave gateway, sum of input and output is 288 bytes. PDF Download : DPM01…
ODOT-PNM02 V2.1 Modbus (master/slave, RTU/ASCII) to ProfiNET, 2 port serial port (RS485/ RS232 / RS422), supports 50 slots, 200 commands in TIA portal (by configured software), support MAX 60 slaves ♦ Supports protocol conversion between Modbus and PROFINET ♦ Supports 2* RS485/RS232 or 1*RS422 ♦ Supports Modbus master or slave, and supports RTU or ASCII ♦ Supports working temperature of…
This is a converter developed by Sichuan Odot Automation System Co., LTD between RS232/485/422 and TCP/UDP.This protocol converter can easily connect serial port devices to Ethernet and realize network upgrade of serial port devices. Protocol converter supports the function of "data transmission", which can be set as a client or a server. This function can easily realize the data communication…
♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP ♦ Supports the connection of5 TCP clients simultaneously ♦ ODOT-S2E2 supports 2*RS485 ♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422 ♦ Each serial port supports Modbus masterand slave ♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway ♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway ♦ Supports one key reset ♦ Gateway working mode: Transparent…
♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP ♦ Supports the connection of5 TCP clients simultaneously ♦ ODOT-S2E2 supports 2*RS485 ♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422 ♦ Each serial port supports Modbus masterand slave ♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway ♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway ♦ Supports one key reset ♦ Gateway working mode: Transparent…
♦ Installed on the PPI/MPI/PROFIBUS communication port of PLC, generally without external powersupply ♦ Support Siemens S7 Ethernet communication drivers, including MicroWIN,STEP7, TIA Portal, WinCC etc. ♦ Integrated with Modbus-TCP server, Modbus data area can be automatically or edited to map to register S7-200/300/400 ♦ S7TCP connection and Modbus-TCP communication can be realized simultaneously ♦ Up to 32 host computer…